Basic Info.
Model NO.
PCM-L04S100-G50
Condition
New
Specified Types
4s Li-ion/Li-Polymer/LiFePO4 Battery
L-Ion/Li-Polymer Charging Voltage
16.8V
LiFePO4 Charging Voltage
14.4V
Max. Continuous Charging Current
100A(Max)
Maximal Continuous Discharging Current
100A(Max)
Discharge Overcurrent Protection
250±50A(Can Adjust)
Colour of PCM
Green
Balance
Yes
Warranty
12 Months
Transport Package
Antistatic Bag /White Box and Standard Export Cart
Specification
L110*W95*T20mm
Trademark
QUAWIN/OEM
Origin
China Guangdong
HS Code
8507909000
Production Capacity
500000/Month
Product Description
Technical parameter
Product name:Protection Circuit Module
Model No:PCM-L04S100-G50
For 4S Lithium-ion/Lithium Polymer/LiFePO4 Battery Packs
Product Feature:
1. Suitable for 12V/100A lead-acid instead of lithium battery protection board;
2. Support 4 battery packs in series;
3. Over charging, over discharging, short circuit, overcurrent, temperature protection, etc;
4. The maximum continuous working current is 100A, and the charging and discharging are at the same port
Items | Specifications | ||
Lithium-ion/Lithium Polymer | LiFePO4 | ||
Charge | Charging voltage(CC/CV)-4S | CC/CV:16.8V | CC/CV:14.4V |
Maximal continuous charging current | 100A(Max) | ||
Discharge | Maximal continuous discharging current | 100A(Max) | |
Low current consumption | Current consumption on operation | <100μA | |
Current consumption at power down | <0.1μA | ||
Cell-balance | Cell-balance detection voltage | 4.20 ± 0.03 V | 3.60 ± 0.03 V |
Cell-balance release voltage | 4.20 ± 0.03 V | 3.60 ± 0.03 V | |
Cell-balance current | 130 ±3mA | 110 ±3mA | |
Over-charge | Overcharge detection voltage | 4.25±0.025V | 3.900 ± 0.025V |
Overcharge release voltage | 4.15±0.05V | 3.800 ± 0.050V | |
Overcharge delay time | 0.5~2S | ||
Over-discharge | Overdischarge detection voltage | 2.50±0.062V | 2.00±0.080V |
Overdischarge release voltage | 3.0±0.075V | 2.30±0.100V | |
Overdischarge delay time | 10~200mS | ||
Discharge overcurrent | Discharge overcurrent detection voltage | 0.2±0.015V | 0.10±0.015V |
Discharge overcurrent delay time | 5~60ms | ||
Discharge overcurrent protection | 250±50A(adjustable) | ||
Release condition | Cut-off-load | ||
Short-circuiting protection | Load short-circuiting detection voltage | / | / |
Detection condition | Exterior short circuit | ||
Load short-circuiting detection delay time | 200~800μs | ||
Release condition | Cut-off-load | ||
Internal resistance | Static Drain-Source On-Resistance | <20mΩ(B- to P-) | |
Temperature | Wide range of operation temperature | 40 ~ + 85ºC | |
Storage Temperature Range | -40 ~ +125ºC | ||
Dimension | L110*W95*T20mm |