Basic Info.
Model NO.
PCM-L04S10-416
Condition
New
Specified Types
4s Li-ion/Li-Polymer/LiFePO4 Battery
L-Ion/Li-Polymer Charging Voltage
16.8V
LiFePO4 Charging Voltage
14.4V
Max. Continuous Charging Current
10A(Max)
Maximal Continuous Discharging Current
10A(Max)
Discharge Overcurrent Protection
25±5A(Can Adjust)
Colour of PCM
Green
Balance
No
Warranty
12 Months
Transport Package
Antistatic Bag /White Box and Standard Export Cart
Specification
L90*W45*T6mm
Trademark
QUAWIN/OEM
Origin
China Guangdong
HS Code
8507909000
Production Capacity
500000/Month
Product Description
Technical parameter
Product name:Protection Circuit Module
Model No:PCM-L04S10-416
For 4S Lithium-ion/Lithium Polymer/LiFePO4 Battery Packs
Product Feature:
1. Suitable for 4 section Lithium-ion/Lithium Polymer/LiFePO4 Battery Packs;
2. Maximum continuous working current 10A, same interface for charging/discharging;
3. Overcharge, overdischarge, short circuit, overcurrent, temperature protection, etc.;
4. Ti BQ20Z95+BQ24618 is adopted.
No. | Test item (Test at normal temperature 25±2ºC and relative humidity≤90%) | Criterion | |
1 | Voltage | Charging voltage(4S) | DC:16.8V CC/CV(4.2V/1Cell) |
2 | Capacity | Designing battery capacity | 3000mAh |
Max capacity(Battery pack) | 150Ah | ||
3 | Current | Current consumption(Firmware running) | <600uA |
Current consumption(Sleep Mode) | <200uA | ||
Maximal continuous charging current | 10A(Max) | ||
Maximal continuous discharging current | 10A(Max) | ||
4 | Over Current (1st Level Safety) | Over charge detection current | 6500mA |
Detection delay time | 2s | ||
Over discharge detection current | 12000mA | ||
Detection delay time | 2s | ||
5 | Over Current (2nd level safty) | Over charge detection current | 8000mA |
Detection delay time | 1s | ||
Over discharge detection current | 15000 | ||
Detection delay time | 1s | ||
Release delay time | 8s | ||
6 | Over charge Protection (for single cell) | Over charge detection voltage | 4.3±0.025V |
Over charge detection delay time | 2S | ||
Over charge release voltage | 3.9±0.05V | ||
Over charge detection release delay time | 20s | ||
7 | Over discharge protection (for single cell) | Over discharge detection voltage | 2.5±0.05V |
Over discharge detection delay time | 2s | ||
Over discharge release voltage | 3.0±0.05V | ||
8 | Over charge Protection(Pack) 1st Level Safety | Over charge detection voltage | 17.5V |
Over charge detection delay time | 2s | ||
Over charge release voltage | 16V | ||
9 | Over charge Protection (Pack) 2nd Level Safety | Over charge detection voltage | 18V |
10 | Over discharge protection(Pack) | Over discharge detection voltage | 11V |
Over discharge detection delay time | 2s | ||
Over discharge release voltage | 12V | ||
Over discharge detection release delay time | 0s | ||
11 | Short protection | Detection condition | Exterior short circuit |
Detection delay time | 200-500us | ||
Release condition | Cut load | ||
12 | Resistance | Protection circuitry(B- to P- and B+ to P+) | ≤100mΩ |
13 | Over temperature protection (1st Level Safety) | Charge | 55ºC±5ºC |
Charge delay time | 2s | ||
Over temperature charge recovery | 50ºC±5ºC | ||
Discharge | 60ºC±5ºC | ||
Discharge delay time | 2s | ||
Discharge delay recovery time | 55ºC±5ºC | ||
14 | Over temperature protection (2nd Level Safety) | Charge | 65ºC±5ºC |
Charge delay time | 0s | ||
Discharge | 75ºC±5ºC | ||
Discharge delay time | 0s | ||
15 | Temperature | Operating Temperature Range | -20~+85ºC |
Storage Temperature Range | -20~+125ºC | ||
Dimension | L90*W45*T6mm |