Fluke 1625-2-Kit Advanced Geo Earth Ground Tester Kit

After-sales Service: Yes
Warranty: 1 Year Warranty
Display Type: Digital Only

Products Details

  • Overview
  • Product Parameters
  • Packaging & Shipping
Overview

Basic Info.

Model NO.
1625-2-KIT
Certification
RoHS, CE
Customized
Non-Customized
Model
1625-2kit
Operating Temperature
14 to 122°f (-10 to 50°c)
Measuring Time
Typical Six Seconds
V Ext Rejection
>120 dB (16²⁄3, 50, 60, 400 Hz)
Measuring Range
0.020 Ω to 19.99 KΩ
Dimensions
45 X 28 X 26 Cm
Weight
7.6 Kg
Transport Package
UPS/DHL/FedEx
Specification
250 x 133 x 187 mm
Trademark
FLUKE
Origin
China
HS Code
9030332000
Production Capacity
50, 000 Pieces/Year

Product Description

Rugged and reliable, this stakeless earth ground clamp is perfect for industrial environments. High-quality, the heavy-duty clamp jaw stays in alignment and calibration, and users can identify ground loop resistance without the need to disconnect then reconnect the earth electrode from the system.
Fluke 1625-2-Kit Advanced Geo Earth Ground Tester Kit

Fluke 1625-2 KIT Advanced GEO Earth Ground Tester Kit

  • 3- and 4-pole Fall of Potential, earth resistance loop testing
  • 4-pole Soil Resistivity testing
  • Selective earth ground rod testing using 1 clamp
  • Stakeless earth ground rod testing using 2 clamps

Simpler, faster earth ground tests than ever before. With internal memory storage of up to 1500 records, users can have a faster setup made easy with the new color-coded wires that help eliminate mistakes.

Features

  • One-button measurement concept
  • 3- and 4-pole earth ground measurement
  • 4-pole soil resistivity testing
  • Selective testing, no disconnection of ground conductor (1 clamp)
  • Stakeless testing, quick ground loop testing (2 clamps)
  • Measuring frequency 128 Hz
Product Parameters

 

Temperature Range
Operating Temperature 14 to 122°F (-10 to 50°C)
Storage Temperature -22 to 140°F (-30 to 60°C)
Temperature Coefficient ±0.1% of reading/°C <18°C >28°C
Error Intrinsic: Refers to the reference temperature range and is guaranteed for one year
Operating: Refers to the operating temperature range and is guaranteed for one year
Climatic Class C1 (IEC 654-1), 23 to 115°F (-5 to 45°C), 5 to 95% RH
Protective Type IP56 for case, IP40 for battery door according to EN60529
Safety Protection by double and/or reinforced insulation maximum 50 V to earth. IEC61010-1: 300V CAT II, Pollution degree two
EMC (Emission Immunity) IEC61326-1: Portable
Quality System Developed, designed, and manufactured according to DIN ISO 9001
External Voltage V external, maximum = 24 V (dc, ac <400 Hz), measurement inhibited for higher values
V Ext Rejection >120 dB (16²⁄3, 50, 60, 400 Hz)
Measuring Time Typical six seconds
Maximum Overload 250 V rms (pertains to misuse)
Auxiliary Power 6 x 1.5 V Alkaline (type AA LR6)
Battery Life Span Typical >3000 measurements
RA 3-Pole Ground Resistance Measurement (IEC 1557-5)
Switch Position RA 3-pole
Resolution 0.001 to 10 Ω
Measuring Range 0.020 Ω to 19.99 kΩ
Accuracy ±(2% rdg + 3 d)
Operating Error ±(5% rdg + 3 d)
Measuring Principle: Current/Voltage Measurement
Measuring Voltage Vm = 48 V ac
Short-Circuit Current >50 mA
Measure Frequency 128 Hz
Probe Resistance (RS) Maximum 100 kΩ
Auxiliary Earth Electrode Resistance (RH) Maximum 100 kΩ
Additional Error from RH and RS RH[kΩ]RS[kΩ]/RA[Ω]0.2%
RA 4-Pole Ground Resistance Measurement (IEC 1557-5)
Switch Position RA 4-pole
Resolution 0.001 to 10 Ω
Measuring Range 0.020 Ω to 19.99 kΩ
Accuracy ±(2% rdg + 3 d)
Operating Error ±(5% rdg + 3 d)
Measuring Principle: Current/Voltage Measurement
Measuring Voltage Vm = 48 V ac
Short-Circuit Current >50 mA
Measure Frequency 128 Hz
Probe Resistance (RS + RES) Maximum 100 kΩ
Auxiliary Earth Electrode Resistance (RH) Maximum 100 kΩ
Additional Error from RH and RS RH[kΩ]RS[kΩ]/RA[Ω]0.2%
Monitoring of RS and RH with error indicator.
Automatic range selection.
RA 3-Pole Selective Ground Resistance Measurement with Current Clamp (RA with Clamp)
Switch Position RA 3-pole with clamp
Resolution 0.001 to 10 Ω
Measuring Range 0.020 Ω to 19.99 kΩ
Accuracy ±(7% rdg + 3 d)
Operating Error ±(10% rdg + 5 d)
Measuring Principle: Current/Voltage Measurement (with External Current Clamp)
Measuring Voltage Vm = 48 V ac
Short-Circuit Current >50 mA
Measure Frequency 128 Hz
Probe Resistance (RS) Maximum 100 kΩ
Auxiliary Earth Electrode Resistance (RH) Maximum 100 kΩ
Monitoring of RS and RH with error indicator.
Automatic range selection.
Measurement is not performed if the current through the current clamp is too low.
RA 4-Pole Selective Ground Resistance Measurement with Current Clamp (RA with Clamp)
Switch Position RA 4-pole with clamp
Resolution 0.001 to 10 Ω
Measuring Range 0.020 Ω to 19.99 kΩ
Accuracy ±(7% rdg + 3 d)
Operating Error ±(10% rdg + 5 d)
Measuring Principle: Current/Voltage Measurement (with External Current Clamp)
Measuring Voltage Vm = 48 V ac
Short-Circuit Current >50 mA
Measure Frequency 128 Hz
Probe Resistance (RS) Maximum 100 kΩ
Auxiliary Earth Electrode Resistance (RH) Maximum 100 kΩ
Monitoring of RS and RH with error indicator.
Automatic range selection.
Measurement is not performed if the current through the current clamp is too low.
Stakeless Ground Loop Measurement (2 Clamps)
Switch Position RA 4-pole 2 clamps
Resolution 0.001 to 10 Ω
Measuring Range 0.020 Ω to 19.99 kΩ
Accuracy ±(7% rdg + 3 d)
Operating Error ±(10% rdg + 5 d)
Measuring Principle: Stakeless Measurement of Resistance in Closed Loops Using Two Current Transformers
Measuring Voltage Vm = 48 V ac
Measure Frequency 128 Hz
Noise Current (IEXT) Maximum IEXT = 10 A (ac) (RA <20 Ω)
General Specifications
Display 1999 Digit LCD: Display with special symbols, digit height 25 mm, fluorescent backlight
User Interface Instant measurement through TURN and START one button concept. The only operating elements are rotary switch and START button
Robust, Water and Dust Resistant Instrument is designed for tough environmental conditions (rubber protective cover, IP56)
Memory Internal memory storage up to 1500 records accessible via USB port
Dimensions 9.75 x 5.25 x 7.35" (250 x 133 x 187 mm)
Weight 2.43 lbs (1.1 kg) including batteries
16.8 lbs (7.6 kg) included accessories and batteries in carrying case
   
Packaging & Shipping
Fluke 1625-2-Kit Advanced Geo Earth Ground Tester Kit
Fluke 1625-2-Kit Advanced Geo Earth Ground Tester Kit
Fluke 1625-2-Kit Advanced Geo Earth Ground Tester Kit
Fluke 1625-2-Kit Advanced Geo Earth Ground Tester Kit
Fluke 1625-2-Kit Advanced Geo Earth Ground Tester Kit
Fluke 1625-2-Kit Advanced Geo Earth Ground Tester Kit

 

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours