Kdzd Single Unit Lead-Acid Battery Charging and Discharging Repair Test Activator/Battery Charging Discharging Machine

Customization: Available
After-sales Service: Online
Warranty: 1 Year

Products Details

Basic Info.

Model NO.
KDZD 48V 100A
HS Code
9024800000
Production Capacity
200pieces/Month

Product Description

KDZD Single unit lead-acid battery charging and discharging repair test activator/battery charging discharging machine

Portable products for the treatment of backward batteries in daily maintenance, it has three modes of use: battery discharge mode, battery charging mode and battery activation mode. According to the actual situation of different backward batteries, the capacity test of backward batteries can be carried out, low-voltage constant current charging, or multiple cycle cycles can be set up to cycle the minimum capacity of the battery for multiple charges and discharge, in order to activate the active substances that fail the battery plate to activate the battery and improve the capacity of the backward battery. At the same time, it is equipped with PC application software to upload the collected data to the computer, which is convenient for various analysis.

KDZD Single unit lead-acid battery charging and discharging repair test activator/battery charging discharging machine

Main function
Single battery activation function:

A single battery can be activated when the battery is in the online floating charge or offline state. Before activation, set the number of activation cycles, single activation charging time, protection voltage parameters, and the instrument will automatically activate; And real-time display of battery voltage, charge/discharge current, charge/discharge capacity, charge/discharge time and other data; The activation process can be stopped when the preset activation cycle is completed or the operation is terminated manually.

Single battery check discharge function:

The activator can carry out constant discharge of single battery, set discharge current, discharge time, discharge capacity, termination voltage and other parameters, the instrument automatically performs discharge function, and displays discharge current, discharge capacity, battery voltage, discharge time and other data in real time. The discharge test can be stopped when the battery reaches the preset discharge termination condition or the operation is stopped manually.

Single battery charging function:

When the battery is in the online floating charge or offline state, the battery can be automatically charged, set the charging current, charging time, termination voltage and other parameters, the instrument will automatically perform the charging function, and real-time display the charging current, the battery has been charged capacity, battery voltage, charging time and other data. When the battery reaches the preset termination charging conditions or artificial termination operation can stop charging.

KDZD Single unit lead-acid battery charging and discharging repair test activator/battery charging discharging machine

Main features:
1. Data storage: Large capacity. It can save 10 sets of activation data, 10 sets of check discharge data and 10 sets of charge test data respectively. Users can query, delete, and export data.
2. With RS232 communication interface and USB interface. The data is transferred to the computer and entered into the database management, which can save and analyze long-term historical data. Use U disk to transfer data, real-time test real-time saving.
3. During the test, when the battery is abnormal or the activator itself is abnormal, the activator automatically terminates the test to protect the battery.
4. Activate the integrated design of monitoring unit and power unit. The monitoring unit adopts high-speed A/D and D/A, which makes the measurement and control more rapid and accurate. The power monomer adopts a new efficiency device.
5. The software is designed in Chinese and can automatically generate voltage and current curves, as well as test reports (including Excel tables and WORD documents).

Model number KDZD832
Cell voltage measurement type 2V/4V//6V/12V/24V
Cell voltage measurement range 2V:0~3V 4V/6V:4~8V 12V:8~15V 24V
Cell voltage resolution 2 V / 4 V / 6 V, 0.001 V, 12 V, 0.01 V. 24 V, 0.01 V
Voltage measurement accuracy 0.50%
Charge and discharge current operating range 2V/4V:2A~50A 6V:2A~30A 12V:2A~30A 24V:2A~30A
Charge and discharge current control accuracy 0. 1A
Current measurement accuracy 1%
Battery capacity check range 20Ah~500Ah 6V:20Ah~300Ah 12V: 20Ah~300Ah 24V: 20Ah~300Ah
Operating voltage AC 220 ± 15%
Communication mode RS232 communication and SD card
Cooling mode Forced air cooling
Working environment Temperature: 0ºC~40ºC Humidity: 20%~80%RH
Storage condition -20ºC~70ºC packaging storage
Display mode 7 "color LCD display
External dimension 210×240×280mm
Touch tape mode portable
heavyThe amount 7KG


Kdzd Single Unit Lead-Acid Battery Charging and Discharging Repair Test Activator/Battery Charging Discharging MachineKdzd Single Unit Lead-Acid Battery Charging and Discharging Repair Test Activator/Battery Charging Discharging MachineKdzd Single Unit Lead-Acid Battery Charging and Discharging Repair Test Activator/Battery Charging Discharging MachineKdzd Single Unit Lead-Acid Battery Charging and Discharging Repair Test Activator/Battery Charging Discharging MachineKdzd Single Unit Lead-Acid Battery Charging and Discharging Repair Test Activator/Battery Charging Discharging Machine